Capteurs pour le domaine de l’infrarouge proche (NIR) et de l'infrarouge moyen (MIR)
26.08.2024
26.08.2024
20.06.2024
Differentiation of recyclate types using NIR during the recycling process The use of more and more recyclates in the plastic processing industry, driven not least by the EU Packaging and Packaging Waste Regulation (PPWR) with regard to the proportion of recyclates in plastics, also increases the need to carry out a check according to the type of plastic of the respective recyclate in addition to the color check already carried out in the laboratory. There is no lack of adequate sensor technology during the sorting and separating process, as various machine builders offer sorting systems equipped with so-called hyperspectral cameras suitable for the NIR range. These are suitable for sorting whole objects as well as for separating plastic fragments and flakes. However, for economic reasons these NIR cameras are less suitable for more selective product monitoring. Discrete sensors and sensor systems, which are both very compact in design and inexpensive to purchase, are more appropriate for this purpose.
In addition to stationary laboratory devices SPECTRO-T-3-0°/45°-LAB-LF and SPECTRO-T-3-DIF/0°-LAB-LF, mobile laboratory systems SPECTRO-T-3-0°/45°-MOBILE-P and SPECTRO-T-3-DIF/0°-MOBILE-P are also available. To avoid sending the measuring systems in for regular recalibration, on-site calibration has been integrated into the devices. (...) |
Differentiation of Plastic Types for Recyclates With the help of the Three-range Methode in the NIR Range |
26.08.2024
Clarity in darkness – Detect in Carbon Black Soot-blackened plastic, like a black hole that devours all light? Not quite! Although a large proportion of the light hitting the black plastic material is absorbed in the visible and near infrared range (NIR), the absorption behavior of Carbon Black products in the mid infrared range (MIR) is rather low compared to light-colored materials. In the MIR range, therefore, a window opens that provides an insight into the type of plastic used. Different Carbon Black plastics have a characteristic spectral absorption behavior in the MIR range, which makes it possible to differentiate between different types of plastic in this wavelength range.
Up to now, black plastic has tended to be downcycled, at least in open cycles, i.e. the recycled material is no longer intended for its original use but is instead used for lesser purposes. In view of the fact that around 1/6 of the plastic material produced each year currently consists of carbon black, there is an increasing need for action to return the recycled material to its original area of application. In the automotive industry in particular, but also in the electronics and construction industries, soot-blackened plastic is predominantly used. At present, however, the range of sorting and separation systems for separating Carbon Black by type of plastic is still limited. This is probably preliminary due to the fact that hyperspectral cameras suitable for the MIR range are still quite expensive and require intensive servicing. Together with partner companies, Sensor Instruments is taking an alternative approach here; the three-range method known from the visible wavelength range has been transferred to the MIR range. L*a*b* became M*i*r* and instead of measuring in the visible range (400nm to 700nm), measurements are taken in the mid-infrared range between 2.5µm and 5.0µm. (...) |
Carbon Black Differentiation Using the Multi-range Method in the MIR Range |
20.06.2024
Déterminer l'épaisseur des couches aussi bien sur les films qu’entre les films plastiques Comment peut-on déterminer l'épaisseur d'une couche de vernis entre deux films PET ?
A cet effet, quatre paires de films PET avec différentes épaisseurs de couche de vernis entre les deux films PET (10µm, 20µm, 50µm et 80µm) ont été examinées avec la méthode de lumière transmise MIR. Du côté du récepteur, on disposait de deux plages de longueurs d'onde avec des longueurs d'onde centrales de 2.95µm et 3.90µm (SPECTRO-M-2-2.95/3.90). La distance entre le film PET et l'émetteur MIR était d'environ 20mm. La présence d'une couche de silicone sur un film plastique transparent a également été examinée à l'aide de cette méthode de mesure, avec pour résultat que cette couche peut également être très bien détectée. |
SPECTRO-M-15-T (source de lumière) + SPECTRO-M-2-2.95/3.90 (récepteur) |