C-LAS Series
Laser compact light barriersGeneral technical data ....
GENERAL TECHNICAL DATA:
Voltage supply | +24VDC (± 10%), reversed-polarity protection, overcurrent protection |
Current cunsumption | <50mA |
Max. switching current | C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-LT-35, C-LAS-LT-65, C-LAS-14: 100mA, short-circuit proof |
Rise time / fall time | C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-14: <200 µs C-LAS-LT-35, C-LAS-LT-65: <=1 ms |
Switching frequency | depends on sensor type |
Light source | Semiconductor laser, 670 nm, opt. power <1 mW, class 2 laser product acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Operation mode | AC-operation (100 kHz) |
Working distance / reference distance |
depends on sensor type |
Laser beam focus | C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-14: Collimated, focused at infinity, beam divergence typ. 1 mrad C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA: at a distance of typ. 50 mm |
Laser spot size | C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2: typ. Ø 1.5 mm beam diameter at light exit at the sensor C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA: typ. <0.2 mm beam diameter in focus (at 50 mm distance) typ. <2 mm beam diameter at light exit at the sensor C-LAS-14: typ. <2 mm beam diameter at light exit at the sensor |
Min. detectable object | C-LAS-LR-OP2, C-LAS-LR-OP2-HS: typ. 0.1 mm C-LAS-LR-RP2: Short range <200 mm: typ. 1 mm Short range <1 m: typ. 3 mm Wide range <5 m: typ. 10 mm Wide range <20 m: typ. 30 mm C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA: typ. 50 µm C-LAS-14: Short range <0.5m: typ. 2 mm Wide range <5 m: typ. 5 mm Wide range >=5 m: typ. 10 mm |
Optical filter | C-LAS-LR-OP2, C-LAS-LR-OP2-HS: Red light filter C-LAS-LR-RP2: Red light filter and polarisation filter C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA, C-LAS-14: Red light filter |
Ambient light | up to 5000 Lux |
Output | depends on sensor type |
Switching state indication | C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-LT-35, C-LAS-LT-65, C-LAS-14: By means of an orange LED (integrated in the M8 connector) |
Operation display | C-LAS-LT-35-ANA, C-LAS-LT-65-ANA: By means of a green LED (integrated in the sensor housing) |
Adjustment of scanning distance | C-LAS-LT-35, C-LAS-LT-65: by means of a potentiometer (can be rotated 270°) |
Adjustment of laser power | C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-14: by means of a potentiometer (can be rotated 270°) |
Laser power correction | C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA: Due to integrated laser power correction, the sensor is largely independent of brightness of measuring object (for instance KODAK white and KODAK black) |
Housing dimensions | approx. 33 mm x 16 mm x 23 mm |
Housing material | Plastic, black |
Type of connector | 4-pole M8-connector |
Connecting cable | to PLC: cab-M8/4-... |
Operating temp. range | -20°C ... +55°C |
Storage tem. range | -20°C ... +85°C |
Enclosure rating | IP67 |
EMC test acc. to | DIN EN 60947-5-2 |