Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

C-LAS Series

Laser compact light barriers


General technical data ....

Type Working distanceMin. detect. objectSwitching frequency/ band width analog signalOutputLight sourceLxWxH (mm) Data
sheet
CAD
data
Appl.
C-LAS-LR-OP2 0...200mm (depends on object)0.1mm1kHzpnp/npn no+nc (2x)Laser, 670nm, <1mW (CL. 2)33x16x23
Appl.
C-LAS-LR-OP2-HS 0...200mm (depends on object)0.1mm20kHzpnp/npn no+nc (2x)Laser, 670nm, <1mW (CL. 2)33x16x23
C-LAS-LR-RP2 0...20m (depends on reflector)1...30mm3kHzpnp/npn no+nc (2x)Laser, 670nm, <1mW (CL. 2)33x16x23
C-LAS-LT-35 25...50mm (reference distance 35mm)50µm1kHzpnp/npn no+nc (2x)Laser, 670nm, <1mW (CL. 2)33x16x23
Appl.
C-LAS-LT-35-ANA 25...50mm (reference distance 35mm)50µmANA 1kHz (-3dB)0...+10V (1x)Laser, 670nm, <1mW (CL. 2)33x16x23
C-LAS-LT-65 40...100mm (reference distance 65mm)50µm1kHzpnp/npn no+nc (2x)Laser, 670nm, <1mW (CL. 2)33x16x23
C-LAS-LT-65-ANA 40...100mm (reference distance 65mm)50µmANA 1kHz (-3dB)0...+10V (1x)Laser, 670nm, <1mW (CL. 2)33x16x23
C-LAS-14 100mm...100m (Transmitter/ Receiver dist.)2...10mm2kHzpnp/npn no+nc (2x)Laser, 670nm, <1mW (CL. 2)33x16x23


GENERAL TECHNICAL DATA:
Voltage supply +24VDC (± 10%), reversed-polarity protection, overcurrent protection
Current cunsumption <50mA
Max. switching current C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-LT-35, C-LAS-LT-65, C-LAS-14:
100mA, short-circuit proof
Rise time / fall time C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-14:
<200 µs
C-LAS-LT-35, C-LAS-LT-65:
<=1 ms
Switching frequency depends on sensor type
Light source Semiconductor laser, 670 nm, opt. power <1 mW,
class 2 laser product acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014)
Operation mode AC-operation (100 kHz)
Working distance /
reference distance
depends on sensor type
Laser beam focus C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-14:
Collimated, focused at infinity, beam divergence typ. 1 mrad
C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA:
at a distance of typ. 50 mm
Laser spot size C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2:
typ. Ø 1.5 mm beam diameter at light exit at the sensor
C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA:
typ. <0.2 mm beam diameter in focus (at 50 mm distance)
typ. <2 mm beam diameter at light exit at the sensor
C-LAS-14:
typ. <2 mm beam diameter at light exit at the sensor
Min. detectable object C-LAS-LR-OP2, C-LAS-LR-OP2-HS:
typ. 0.1 mm
C-LAS-LR-RP2:
Short range <200 mm: typ. 1 mm
Short range <1 m: typ. 3 mm
Wide range <5 m: typ. 10 mm
Wide range <20 m: typ. 30 mm
C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA:
typ. 50 µm
C-LAS-14:
Short range <0.5m: typ. 2 mm
Wide range <5 m: typ. 5 mm
Wide range >=5 m: typ. 10 mm
Optical filter C-LAS-LR-OP2, C-LAS-LR-OP2-HS:
Red light filter
C-LAS-LR-RP2:
Red light filter and polarisation filter
C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA, C-LAS-14:
Red light filter
Ambient light up to 5000 Lux
Output depends on sensor type
Switching state indication C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-LT-35, C-LAS-LT-65, C-LAS-14:
By means of an orange LED (integrated in the M8 connector)
Operation display C-LAS-LT-35-ANA, C-LAS-LT-65-ANA:
By means of a green LED (integrated in the sensor housing)
Adjustment of scanning distance C-LAS-LT-35, C-LAS-LT-65:
by means of a potentiometer (can be rotated 270°)
Adjustment of laser power C-LAS-LR-OP2, C-LAS-LR-OP2-HS, C-LAS-LR-RP2, C-LAS-14:
by means of a potentiometer (can be rotated 270°)
Laser power correction C-LAS-LT-35, C-LAS-LT-35-ANA, C-LAS-LT-65, C-LAS-LT-65-ANA:
Due to integrated laser power correction, the sensor is largely independent of brightness of measuring object (for instance KODAK white and KODAK black)
Housing dimensions approx. 33 mm x 16 mm x 23 mm
Housing material Plastic, black
Type of connector 4-pole M8-connector
Connecting cable to PLC: cab-M8/4-...
Operating temp. range -20°C ... +55°C
Storage tem. range -20°C ... +85°C
Enclosure rating IP67
EMC test acc. to DIN EN 60947-5-2