Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

A-LAS Series Electronic Control Units

Electronic control units for laser analog light barriers or fiber optics


General technical data ....

Type Suitable forMin. detectable objectSwitching frequencyAnalog band widthInputsOutputsLxWxH (mm) Data
sheet
CAD
data
Appl.
A-LAS-CON1 A-LAS sensors (max. 2)<10µm (depends on the aperture of the A-LAS sensor)max. 25kHz10kHz (-3dB)2x DIG (IN0, IN1)1xANA (0...10V), 3x DIG (OUT0... OUT2)110x70x30
Appl.
A-LAS-CON1-4/20 A-LAS sensors (max. 2)<10µm (depends on the aperture of the A-LAS sensor)max. 25kHz10kHz (-3dB)2x DIG (IN0, IN1)1xANA (4...20mA), 3x DIG (OUT0... OUT2)110x70x30
A-LAS-CON1-FIO Fiber optics of FIO Series (max. 2)<10µm (depends on the cross-section of the fiber optics)max. 25kHz10kHz (-3dB)2x DIG (IN0, IN1)1xANA (0...10V), 3x DIG (OUT0... OUT2)110x70x30
Appl.
A-LAS-CON1-FIO-
4/20
Fiber optics of FIO Series (max. 2)<10µm (depends on the cross-section of the fiber optics)max. 25kHz10kHz (-3dB)2x DIG (IN0, IN1)1xANA (4...20mA), 3x DIG (OUT0... OUT2)110x70x30
SI-CON4 A-LAS sensor<10µm (depends on the aperture of the A-LAS sensor)max. 6kHz1kHz (-3dB)---1xANA (0...10V), 1x DIG (Q or Qinv)60x40x22
SI-CON8 A-LAS sensor<10µm (depends on the aperture of the A-LAS sensor)max. 30kHz1kHz (-3dB)1x DIG (IN0)1xANA (0...10V), 2x DIG (OUT0, OUT1)60x50x22
Appl.
SI-CON8-FIO Lichtleiter der FIO Serie<10µm (depends on the cross-section of the fiber optics)max. 30kHz10kHz (-3dB)1x DIG (IN0)1xANA (0...10V), 2x DIG (OUT0, OUT1)60x50x22
SI-CON11-0/20 A-LAS sensordepends on the aperture of the A-LAS sensor---200kHz (-3dB)---1xANA (0...10V), 1x ANA (0...20mA)65x27x30
SI-CON11-0/20-IC A-LAS sensordepends on the aperture of the A-LAS sensor---200kHz (-3dB)I-CONTROL (0...5V)1xANA (0...10V), 1x ANA (0...20mA)65x27x30
SI-CON11-4/20 A-LAS sensordepends on the aperture of the A-LAS sensor---200kHz (-3dB)---1xANA (0...10V), 1x ANA (4...20mA)65x27x30
SI-CON11-4/20-IC A-LAS sensordepends on the aperture of the A-LAS sensor---200kHz (-3dB)I-CONTROL (0...5V)1xANA (0...10V), 1x ANA (4...20mA)65x27x30
SI-CON11-5/25 A-LAS sensordepends on the aperture of the A-LAS sensor---200kHz (-3dB)---1xANA (0...10V), 1x ANA (5...25mA)65x27x30
SI-CON11-5/25-IC A-LAS sensordepends on the aperture of the A-LAS sensor---200kHz (-3dB)I-CONTROL (0...5V)1xANA (0...10V), 1x ANA (5...25mA)65x27x30
AGL3 A-LAS sensor< 10µm (depends on the aperture of the A-LAS sensor)25kHz50kHz (-3dB)---1xANA (0...55V), 1xANA (0...10V), 2x DIG STAT, 2x DIG DYN (PULSE)60x27x27
AGL4-Q A-LAS sensor< 10µm (depends on the aperture of the A-LAS sensor)25kHz50kHz (-3dB)---1xANA (0...10V), 1xANA (0...10V), 2x DIG STAT, 1x DIG DYN (PULSE)65x27x30
Appl.
AGL4-Qinv A-LAS sensor< 10µm (depends on the aperture of the A-LAS sensor)25kHz50kHz (-3dB)---1xANA (0...10V), 1xANA (0...10V), 2x DIG STAT, 1x DIG DYN (PULSE\)65x27x30
AGL4-Q-HS-
500kHz-24V_LED
A-LAS sensor< 10µm (depends on the aperture of the A-LAS sensor)500kHz0...+10V: 500kHz (-3dB), 4...20mA: 100kHz (-3dB)---1xANA (0...10V), 1xANA (0...10V), 2x DIG STAT, 1x DIG DYN (PULSE)65x27x30
AGL4-Qinv-HS-
500kHz-24V_LED
A-LAS sensor< 10µm (depends on the aperture of the A-LAS sensor)500kHz0...+10V: 500kHz (-3dB), 4...20mA: 100kHz (-3dB)---1xANA (0...10V), 1xANA (0...10V), 2x DIG STAT, 1x DIG DYN (PULSE)65x27x30
AGL-DIF A-LAS sensor< 10µm (depends on the aperture of the A-LAS sensor)25kHz50kHz (-3dB)---1xANA (0...10V), 1xANA (0...10V), 2x DIG STAT, 1x DIG DYN (PULSE)65x24x36


GENERAL TECHNICAL DATA:
Software with A-LAS-CON1 (-4/20), A-LAS-CON1-FIO (-4/20):
Windows® PC software: A-LAS-CON1-Scope
with SI-CON4:
Windows® PC software: A-LAS-Scope
with SI-CON8, SI-CON8-FIO:
Windows® PC software: SI-CON8-Scope
Voltage supply +24VDC (± 10%), reserve polarity protected, overload protected
Current consumption <200mA
Max. switching current 100mA, short circuit proof
Min. detectable object depends on the aperture of A-LAS sensor or
on the cross section of the fiber optics used (in case of type -FIO)
Resolution depends on sensor type
Input digital depends on sensor type
Output digital depends on sensor type
Output analog depends on sensor type
Band  width analog signal depends on sensor type
Interface with A-LAS-CON1 (-4/20), A-LAS-CON1-FIO (-4/20), SI-CON4, SI-CON8, SI-CON8-FIO:
RS232 (USB and Ethernet adapter available)
Switching frequency depends on sensor type
Sensitivity setting depends on sensor type
Threshold correction depends on sensor type
Current input control depends on sensor type
Teach button depends on sensor type
LED indication depends on sensor type
Potentiometer depends on sensor type
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in blue
(fiber optics connector in case of type -FIO: Aluminum, anodized in black)
Connector type depends on sensor type
Connecting cables depends on sensor type
Operating temp. range depends on sensor type
Storage temp. range depends on sensor type
Enclosure rating in case of A-LAS-CON1 (-4/20), A-LAS-CON1-FIO (-4/20): IP54
in case of SI-CON4, SI-CON8, SI-CON8-FIO, SI-CON11-..., AGL3, AGL4, AGL4-...-HS, AGL-DIF: IP64
EMC test acc. to DIN EN 60947-5-2





TOP