Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

A-LAS-N Series Light Barriers/Frontends

Laser analog light barriers for contrast measurement with SPECTRO-1-CONLAS or SPECTRO-1-CONLAS V2.0


General technical data ....

Type Variants (fork sizes)for use withMeas. range/ size of aperture (mm)Distance transm./ receiv.Min. detect. object (typ.)Light sourceLxWxH
(mm)
Data
sheet
CAD
data
Appl.
A-LAS-N-12/90-...-C as pict., various cable lengthsSPECTRO-1-CONLAS, SPECTRO-2-CONLAStyp. up to 6.5mm / Ø0.15...Ø3.0 or 0.2x1...6.5x0.8Max. 10 m (depends on the aperture used an on cable length)0,8% of aperture sizeLaser, 670nm, <0.39mW (CL. 1), focused laser beamT+R: each 68x12x17
A-LAS-N-F08-FOC-...-C 10/50 ... 100/80, various cable lengthsSPECTRO-1-CONLAS, SPECTRO-2-CONLAS0,5 mm or 1,0 mm= Fork width (10...100)0,1% of aperture sizeLaser, 670nm, <0.39mW (CL. 1), focused laser beamcf. data sheet
A-LAS-N-F12-FOC-...-C 20/50 ... 100/80, various cable lengthsSPECTRO-1-CONLAS, SPECTRO-2-CONLAS0,5 mm or 1,0 mm= Fork width (20...100)0,1% of aperture sizeLaser, 670nm, <0.39mW (CL. 1), focused laser beamcf. data sheet
A-LAS-N-M18-...-C M18 housing, various cable lengthsSPECTRO-1-CONLAS, SPECTRO-2-CONLASup to 7 mm (depending on aperture size)Max. 10 m (depends on the aperture used an on cable length)1% of aperture sizeLaser, 670nm, <0.39mW (CL. 1), focused laser beamT+R: each length 90.5 mm x M18x1


GENERAL TECHNICAL DATA:
Light source Solid-state laser, 670 nm, <0.39mW opt. power, DC-operation,
Laser class 1 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014)
Aperture sizes depends on sensor type
Measuring range depends on sensor type
Min. detectable object depends on sensor type
Reproducibility depends on sensor type
Threshold correction can be activated via a software-controlled electronics
(SPECTRO-1-CONLAS, SPECTRO-2-CONLAS)
Optical filter depends on sensor type
Voltage supply Transmitter: +5VDC, receiver: +5VDC
Ambient light with 5000 Lux ambient light around optical receiver unit typ. <300mV
influence on analog signal (0...+10V), depends on the aperture used
Analog output 0...+10V or 4...mA in connection with an electronic control unit
(SPECTRO-1-CONLAS, SPECTRO-2-CONLAS)
Band width analog signal 100kHz (-3dB)
Current control input 0V ... +5V, laser power decreases linear to increase of voltage:
0V: full power, 5V: laser off
Sensitivity setting
(switching threshold)
via a software-controlled electronics
(SPECTRO-1-CONLAS, SPECTRO-2-CONLAS)
Gain (analog signal) via a software-controlled electronics
(SPECTRO-1-CONLAS, SPECTRO-2-CONLAS)
Current consumption Transmitter: typ. <50mA, receiver: typ. <20mA
Housing dimensions depends on sensor type
Housing material depends on sensor type:
anodized in black or blue
Type of connector depends on sensor type
Connecting cables depends on sensor type
Operating temp. range 0°C ... +50°C
Storage temp. range -20°C ... +85°C
Enclosure rating depends on sensor type: IP67 or IP54
EMC test acc. to DIN EN 60947-5-2






TOP