R-LAS-LR-R Series
Laser Reflex Barriers (for Use with Reflector)General technical data ....
GENERAL TECHNICAL DATA:
Software | ►with R-LAS-LR-R: Windows® PC software: LR-Scope ►with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: Windows® PC software: LR-Scope V2.31 |
Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
Current consumption | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: <110mA with R-LAS-LR-RP: <100mA |
Max. switching current | 100mA, short-circuit proof |
Light source | Semi-conductor laser, 670 nm, <0.39mW opt. power, AC-operation, Laser class 1 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Min. detectable object | depends on sensor type |
Working range | depends on sensor type |
Beam geometry | depends on sensor type |
Optical filter | Red light filter, interference filter and polarization filter |
Ambient light | up to 5000 Lux |
Operating mode | Alternating light (100 kHz) |
Outputs | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: 1x digital output (Qinv or Q, adjustable via PC) 1x analog output (0 ... +10V) with R-LAS-LR-RP: 2x digital output (Qinv and Q) |
Switching frequency | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: typ. 6kHz (depends on parameter setting) with R-LAS-LR-RP: typ. 1kHz |
Pulse lengthening | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: parameterizable under Windows® |
Bright-/dark-switching | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: parameterizable under Windows® |
Sensitivity (switching threshold) | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: parameterizable under Windows® with R-LAS-LR-RP: adjustable via potentiometer |
Switching state indicator | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: by means of an orange LED integrated in the M8 housing with R-LAS-LR-RP: by means of a two-color LED (yellow-green) integrated in the housing |
Potentiometer | with R-LAS-LR-RP: 3-revolutions potentiometer for adjustment of switching threshold |
Averaging | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: parameterizable under Windows® |
Housing dimensions | depends on sensor type |
Housing material | Aluminum, anodized in blue |
Type of connector | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: - to PLC: 4-pole M8-connector - to PC: 5-pole fem. conector Binder 712 with R-LAS-LR-RP: - tp PLC: 4-pole M8-connector |
Connecting cables | with R-LAS-LR-R, R-LAS-LR-R-CYL, R-LAS-LR-CYL-RAN: - to PLC: cab-M8/4 - to PC: cab-las5/PC, cab-5/USB or cab-5/ETH with R-LAS-LR-RP: - to PLC: cab-M8/4 |
Operating temp. range | -20°C ... +55°C |
Storage temp. range | -20°C ... +85°C |
Enclosure rating | IP67 |
EMC test acc. to | DIN EN 60947-5-2 |
Interface | RS232 (not available with R-LAS-LR-RP) |